Open-execution manual transfer switches for panel builders — the standard generator changeover used inside UAE main distribution boards.
• 63A to 1600A, 4 pole with switched neutral
• Open execution for plate mounting inside a panel
• Break-before-make with a positive off position — sources can never parallel
• AC-23A to IEC 60947-3, all poles including neutral rated at 100%
• Telescopic shaft for door-depth adjustment, door interlock and padlock facility
• Provision for 2NO + 2NC auxiliary contacts
These are the open-execution changeover switches that go inside a main distribution board. There is no enclosure: the mechanism mounts on the panel plate, a telescopic shaft carries the drive out to a handle on the door, and the panel builder adds the busbar work and the enclosure to suit the job. That is why the range runs all the way from 63A to 1600A while the enclosed and DIN rail versions cover only the lower end — above a couple of hundred amps, the switch belongs in a purpose-built panel.
All units on this page are 4 pole. The fourth pole switches the neutral, and on a generator transfer that is not optional: the utility neutral and the generator neutral are separately earthed, and linking them through an unswitched neutral creates a circulating current path and undermines earth fault discrimination on both sources. All poles, neutral included, are rated at 100% of the nameplate current.
The mechanism is manual and break-before-make. Turning the handle takes the load from source I, through a defined off position, to source II. Quick make-and-break action with self-cleaning contacts means the contact speed does not depend on how fast the operator turns the handle, which is what keeps the arc short and the contacts serviceable over thousands of operations. The AC-23A rating to IEC 60947-3 covers switching inductive and motor loads, including breaking a stalled motor current.
Practical points when specifying. Check the door depth before ordering the shaft — the telescopic shaft adjusts, but only within a range. If the board needs status indication or an interlock to a BMS or an ATS controller, order the 2NO + 2NC auxiliary contact block with the switch rather than retrofitting it. The door interlock and padlock facility should be used, not bypassed; it is what lets a maintenance team lock the switch in a known position. And if the transfer has to be automatic rather than operator-initiated, this is the wrong product family — you want an ATS.
Common applications: hospital and clinic essential boards, data centre and telecom rooms, hotel and mall standby supplies, labour accommodation, industrial plant utility boards, and any commercial building in the UAE with a diesel standby set.